Topics: AIX, SAN, SDD, System Admin

Method error when running cfgmgr

If you see the following error when running cfgmgr:

Method error (/usr/lib/methods/fcmap >> /var/adm/essmap.out):
        0514-023 The specified device does not exist in the
                 customized device configuration database.
This is caused when you have ESS driver filesets installed, but no ESS (type 2105) disks in use on the system. Check the type of disks by running:
# lsdev -Cc disk | grep 2105
If no type 2105 disks are found, you can uninstall any ESS driver filesets:
# installp -u ibm2105.rte ibmpfe.essutil.fibre.data ibmpfe.essutil.rte




If you found this useful, here's more on the same topic(s) in our blog:


UNIX Health Check delivers software to scan Linux and AIX systems for potential issues. Run our software on your system, and receive a report in just a few minutes. UNIX Health Check is an automated check list. It will report on perfomance, capacity, stability and security issues. It will alert on configurations that can be improved per best practices, or items that should be improved per audit guidelines. A report will be generated in the format you wish, and the report includes the issues discovered and information on how to solve the issues as well.